BBYCL - B-LACTAMASE TEST
- MSDS: BBYCL
- Manufacturer: AMERICAN MICROSCAN
- Product Name: B-LACTAMASE TEST
- National Stock Number: 6810-00F007492
Product Identification
Product ID:B-LACTAMASE TEST
MSDS Date:09/01/1984
FSC:6810
NIIN:00F007492
MSDS Number: BBYCL
Responsible Party
SACRAMENTO, CA 95819
Emergency Phone: (916) 739-6033
Info Phone: (916) 739-6033
Cage: OOO14
Contractor
Telephone: (916) 739-6033
Cage: OOO14
Ingredients
IODINE
CAS: 7553-56-2
RTECS: NN1575000
Fraction By Weight: 0.2%
OSHA PEL C 0.1 PPM
ACGIH TLV: C 0.1 PPM; 9192
POTASSIUM IODIDE
CAS: 7681-11-0
RTECS: TT2975000
Fraction By Weight: 5.3%
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: BAL
Hazards
LD50 LC50 Mixture:ORL-MUS LD50 1862MG/KG
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES & SKIN IRRITATION. GASTRIC PAIN,
VOMITING, SWELLING OF LARYNX
Explanation of Carcinogenicity:NONE
Effects of Overexposure:LOSS OF APPETITE, DEPRESSION. HYPERSENSITIVITY
REACTIONS.
First Aid
First Aid:EYE & SKIN: RINSE WLL W/PLENTY OF WATER FOR AT LEAST 15 MINS
AND CALL PHYSICIAN. REMOVE CONTAMINATED CLOTHING. INHALATION:
REMOVE FROM EXPOSURE. GIVE ARTIFICIAL RESPIRATION IF BREATHING HAS
STOPPED. C ALL PHYSICIAN. INGESTION: RINSE MOUTH. GIVE PLENTY OF
WATER TO DRINK, IF CONSCIOUS. CALL PHYSICIAN. NOTE: ANY SUSPICION
OF INFECTION MUST BE REFERRED TO A PHYSICIAN.
Fire Fighting
Extinguishing Media:CO2, DRY CHEMICAL, WATER
Fire Fighting Procedures:AIR MASK SHOULD BE WORN.
Unusual Fire/Explosion Hazard:REACTS VIOLENTLY OR EXPLOSIVELY UPON
CONTACT WITH ALKALI METALS OR PERCHLORIC ACID. WHEN HEAT, RELEASES
TOXIC IODINE VAPORS.
Accidental Release
Spill Release Procedures:WEAR SUITABLE PROTECTIVE CLOTHING, FLUSH TO
SEWER. WASH SPILL AREA WELL WITH SOAP & WATER. ALTERNATIVELY, PICK
UP MATERIAL ON INERT ABSORBANT & SWEEP UP.
Handling
Handling and Storage Precautions:STORE IN A WELL-CLOSED LIGHT-RESISTANT
CONTAINER IN A DRY AREA. AVOID CONTACT WITH EYES & PROLONGED
CONTACT W/SKIN. AVOID BREATHING VAPOR.
Other Precautions:WASH THOROUGHLY AFTER HANDLING. APPROPRIATE
PRECAUTIONS MUST BE USED IN WORKING WITH THE POTENTIALLY PATHOGENIC
TEST ORGANISMS ASSOCIATED WITH THE USE OF THIS PRODUCT.
Exposure Controls
Respiratory Protection:APPROVED MIST RESPIRATOR, IF MIST INVOLVED.
Ventilation:MECHANICAL
Protective Gloves:RUBBER
Eye Protection:SAFETY GLASSES
Other Protective Equipment:APPROVED PROTECTIVE WORK CLOTHES
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:212F
Spec Gravity:1.0
Evaporation Rate & Reference:EQUAL TO WATER
Solubility in Water:MISCIBLE
Appearance and Odor:TRANSPARENT VIOLET-BLACK SOLUTION
Percent Volatiles by Volume:95%
Stability
Stability Indicator/Materials to Avoid:YES
STRONG REDUCERS, ACIDS, METALLIC SALTS, ALKALOIDAL SALTS; ACETYLENE,
ETHYL ALCOHOL, TARTARIC ACID CHLORAL HYDRATE
Stability Condition to Avoid:EXCESSIVE HEAT. CONTACT W/ALKALI METALS,
PERCHLORIC ACID.
Hazardous Decomposition Products:THERMAL DECOMPOSITION TO YIELD TOXIC
IODINE, HI
Disposal
Waste Disposal Methods:FLUSH LIQUID TO SEWER OR DISPOSE OF ABSORBED
MATERIAL TO A LANDFILL BY WAY OF A LICENSED CONTRACTOR.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their